TCN’S DUTY IS GRID INTEGRITY MAINTENANCE
![]() |
MINISTER OF POWER |
The Transmission Company of Nigeria, TCN has come out to make
clarifications on some issues bordering on its concerns.
The clarification which was made through a press statement signed
by its General Manager (Public Affairs) Transmission Company of Nigeria), Mr. Seun
Olagunju, who noted that the attention of the Transmission Company of Nigeria
has been drawn to some recent reports of request to generation companies to “ramp
down”.
According to the statement, “in general, electricity is not stored
but is used as it is being generated”.
“Therefore at any particular moment in time, there is a power flow
balance equation that determines system frequency, with the target of operating
at 50HZ frequency”, the statement read.
The GM, Public Affairs disclosed that; “it is the duty of the
System Operator to monitor the power flow on the national grid to ensure
optimal operating conditions; this will ensure the system is operated at a
frequency close to 50HZ, and at voltages within tolerable limits”.
“Recently, high system frequency (more than 50HZ) has been
observed, necessitating corrective measures. The options to bring down the
frequency to 50Hz are:
(a) Distribution Companies to absorb more load
(b) Generation companies to reduce generation.
The first option is the appropriate line of action. However, due
to inexplicable reasons, some DISCOs failed to take more load as generation
increases. This has left the System Operator with no other option than to ask
the GENCOs to reduce generation to ensure grid stability. The directive to
GENCOs to reduce generation is imperative to maintain the integrity of the
grid, as frequency higher than 50HZ could result in system disturbance. It is
important to note that the directives are issued with a high sense of duty and
responsibility to the nation and the entire electricity industry”, the
statement further stated.
Speaking further, Mr. Olagunju stated that,”the System Operators’
decision is based on the fact that at normal operating frequency of 50Hz, the
active power generated is equal to the active load consumed and losses.
However, if the generated power is more than the load connected, the frequency
rises higher than 50Hz, which can result in system disturbance. To correct this
imbalance, the system operator whose duty it is to maintain system stability
has no choice than to ask the generating stations to drop the load to sustain
the network integrity. This is the practice all over the world”, he said.
On the contrary, if the load connected is higher than the
generated power, the frequency drops below 50Hzand can also lead to system
collapse.
This year, the highest generation level stands at 4,650MW while
the wheeling capacity of TCN is 6,500MW. It is therefore not a wheeling
capacity challenge but a demand side management problem from some DISCOs
rejecting available power.
As
the nation’s transmission company, we understand the importance of our role in
the power sector value chain and the effect our decisions and directives may
have on the quantum of power transmitted to end users. We also know that power
supply is very important for our socio-economic development. Load management
decisions at the level of transmission are taken with high sense of duty to the
nation and for the growth of the power sector, the statement concluded